確定配電箱的額定電流,需要綜合考量所連接設(shè)備的用電需求、線路承載能力及使用場(chǎng)景,通過科學(xué)計(jì)算與合理預(yù)留,確保配電箱既能滿足正常運(yùn)行,又能應(yīng)對(duì)突發(fā)情況,保障用電。
To determine the rated current of the distribution box, it is necessary to comprehensively consider the power demand of the connected equipment, the carrying capacity of the line, and the usage scenario. Through scientific calculation and reasonable reservation, it is ensured that the distribution box can meet both normal operation and emergency situations, ensuring electrical safety.
,需精準(zhǔn)統(tǒng)計(jì)所有接入設(shè)備的總電流。配電箱的額定電流必須大于或等于所連接設(shè)備的總工作電流,這是基本的原則。計(jì)算總電流時(shí),需先明確各設(shè)備的額定功率,再根據(jù)公式 “電流 = 功率 ÷ 電壓”(單相設(shè)備電壓取 220V,三相設(shè)備取 380V)換算出單臺(tái)設(shè)備的額定電流。例如,一臺(tái)功率為 2.2kW 的單相電機(jī),其額定電流約為 10A;一臺(tái) 5.5kW 的三相水泵,額定電流約為 11A。將所有設(shè)備的額定電流相加,得到總電流值,但需注意,部分設(shè)備(如空調(diào)、電焊機(jī))啟動(dòng)時(shí)會(huì)產(chǎn)生沖擊電流,需將其啟動(dòng)電流納入考量 —— 通常電機(jī)類設(shè)備的啟動(dòng)電流為額定電流的 5-7 倍,可按總電流的 1.2-1.5 倍作為參考,避免配電箱因啟動(dòng)瞬間過載而跳閘。
Firstly, it is necessary to accurately calculate the total current of all connected devices. The rated current of the distribution box must be greater than or equal to the total operating current of the connected equipment, which is the most basic principle. When calculating the total current, it is necessary to first clarify the rated power of each device, and then convert the rated current of a single device according to the formula "current=power ÷ voltage" (220V for single-phase equipment and 380V for three-phase equipment). For example, a single-phase motor with a power of 2.2kW has a rated current of about 10A, and a three-phase water pump with a power of 5.5kW has a rated current of about 11A. Adding up the rated currents of all devices gives the total current value, but it should be noted that some devices (such as air conditioners and welding machines) may generate surge currents when starting, and their starting currents need to be taken into account - usually the starting current of motor equipment is 5-7 times the rated current, and 1.2-1.5 times the total current can be used as a reference to avoid tripping the distribution box due to instantaneous overload during starting.
其次,需結(jié)合線路的載流量進(jìn)行匹配。配電箱的額定電流不能超過進(jìn)線電纜的載流量,否則會(huì)導(dǎo)致線路過熱,存在火災(zāi)風(fēng)險(xiǎn)。不同規(guī)格的電纜(如銅芯線、鋁芯線)在不同敷設(shè)環(huán)境(如穿管、明敷、高溫環(huán)境)下的載流量存在差異,例如 10 平方毫米的銅芯電纜在明敷時(shí)載流量約為 65A,穿管敷設(shè)時(shí)可能降 50A。選擇配電箱額定電流時(shí),需參考電纜的實(shí)際載流量,確保兩者匹配,若電纜載流量小于設(shè)備總電流,需先更換更粗的電纜,再確定配電箱額定電流,形成 “設(shè)備 - 配電箱 - 線路” 的電流適配閉環(huán)。
Secondly, it is necessary to match the current carrying capacity of the line. The rated current of the distribution box cannot exceed the maximum current carrying capacity of the incoming cable, otherwise it may cause overheating of the line and pose a fire risk. The current carrying capacity of cables of different specifications (such as copper core wire and aluminum core wire) varies in different laying environments (such as conduit, exposed laying, and high temperature environment). For example, a 10 square millimeter copper core cable has a current carrying capacity of about 65A when exposed, and may drop to 50A when laid in conduit. When selecting the rated current of the distribution box, it is necessary to refer to the actual current carrying capacity of the cable to ensure that they match. If the current carrying capacity of the cable is less than the total current of the equipment, a thicker cable should be replaced first, and then the rated current of the distribution box should be determined to form a current adaptation loop of "equipment distribution box line".
使用場(chǎng)景與工作方式也會(huì)影響額定電流的確定。對(duì)于長期連續(xù)運(yùn)行的配電箱(如工廠生產(chǎn)線的動(dòng)力配電箱),由于設(shè)備持續(xù)工作,發(fā)熱積累明顯,額定電流需在總電流的基礎(chǔ)上增加 20%-30% 的余量,以應(yīng)對(duì)長時(shí)間運(yùn)行帶來的負(fù)荷波動(dòng)。而對(duì)于間歇性工作的配電箱(如建筑工地的臨時(shí)配電箱),設(shè)備并非同時(shí)啟動(dòng),可適當(dāng)降低余量,通常按總電流的 1.1-1.2 倍計(jì)算即可。此外,若配電箱所在環(huán)境溫度較高(如夏季戶外、靠近熱源),或存在粉塵、潮濕等情況,需進(jìn)一步提高額定電流的預(yù)留比例,因?yàn)楦邷貢?huì)降低電器元件的載流能力,惡劣環(huán)境可能加速設(shè)備老化,預(yù)留足夠余量能提升配電箱的耐用性。
The usage scenario and working mode can also affect the determination of rated current. For distribution boxes that operate continuously for a long time (such as power distribution boxes on factory production lines), due to the continuous operation of the equipment and significant heat accumulation, the rated current needs to be increased by 20% -30% margin on the basis of the total current to cope with load fluctuations caused by long-term operation. For distribution boxes that work intermittently (such as temporary distribution boxes on construction sites), the equipment does not start at the same time, and the margin can be appropriately reduced, usually calculated at 1.1-1.2 times the total current. In addition, if the temperature of the environment where the distribution box is located is high (such as outdoors in summer, near heat sources), or there is dust, humidity, etc., it is necessary to further increase the reserve ratio of the rated current, because high temperature will reduce the current carrying capacity of electrical components, and harsh environments may accelerate equipment aging. Adequate margin can be reserved to improve the durability of the distribution box.

電器元件的選型對(duì)額定電流起決定性作用。配電箱內(nèi)部的斷路器、隔離開關(guān)等核心元件,其額定電流需與配電箱的額定電流保持一致,例如額定電流為 100A 的配電箱,應(yīng)配備 100A 的主斷路器。斷路器的脫扣電流設(shè)置也需合理,瞬時(shí)脫扣電流通常為額定電流的 5-10 倍,既能在設(shè)備啟動(dòng)時(shí)避開沖擊電流,又能在發(fā)生短路故障時(shí)快速跳閘,保護(hù)線路和設(shè)備。同時(shí),元件的與質(zhì)量需可靠,避免因元件過載能力不足導(dǎo)致額定電流 “虛標(biāo)”,實(shí)際使用中需通過正規(guī)渠道采購符合標(biāo)準(zhǔn)的元件,確保其承載能力與標(biāo)稱值一致。
The selection of electrical components plays a decisive role in determining the rated current. The rated current of core components such as circuit breakers and isolating switches inside the distribution box should be consistent with the rated current of the distribution box. For example, a distribution box with a rated current of 100A should be equipped with a 100A main circuit breaker. The tripping current setting of the circuit breaker should also be reasonable. The instantaneous tripping current is usually 5-10 times the rated current, which can avoid surge current during equipment startup and quickly trip in case of short circuit faults, protecting the circuit and equipment. At the same time, the brand and quality of the components need to be reliable to avoid "false labeling" of the rated current due to insufficient overload capacity of the components. In actual use, components that meet national standards should be purchased through formal channels to ensure that their load-bearing capacity is consistent with the nominal value.
,需參考相關(guān)規(guī)范與標(biāo)準(zhǔn)。電氣設(shè)計(jì)需遵循電氣安裝規(guī)范,不同場(chǎng)所的配電箱有不同的要求 —— 住宅配電箱的額定電流通常根據(jù)戶型大小確定,小戶型多為 63A,大戶型可達(dá) 100A;商業(yè)場(chǎng)所(如、辦公樓)的配電箱需根據(jù)租賃商戶的用電需求分段設(shè)計(jì),總進(jìn)線配電箱額定電流可能達(dá)到 250A 以上。在計(jì)算過程中,可借助電氣設(shè)計(jì)手冊(cè)中的數(shù)據(jù)圖表,結(jié)合實(shí)際情況調(diào)整,必要時(shí)咨詢電氣人員,確保額定電流的確定既符合標(biāo)準(zhǔn),又能滿足實(shí)際使用需求。
Finally, it is necessary to refer to relevant specifications and standards. Electrical design must comply with electrical installation standards, and distribution boxes in different locations have different requirements - the rated current of residential distribution boxes is usually determined based on the size of the unit, with small units typically rated at 63A and large units up to 100A; distribution boxes in commercial areas (such as shopping malls and office buildings) need to be designed in sections according to the electricity needs of tenants, and the rated current of the total incoming distribution box may reach 250A or more. During the calculation process, data charts in the electrical design manual can be used to adjust according to the actual situation. If necessary, professional electrical personnel can be consulted to ensure that the determination of the rated current meets both safety standards and actual usage needs.
This article is a friendly contribution from Shandong MNS low-voltage drawer cabinet For more information, please click: http://www.gototech.cn We will provide detailed answers to your questions. You are welcome to log in to our website and leave a message